" 30M+ Google Gemini tokens went into researching, analyzing, and understanding all 233 SIH problem statements to make them easier to explore and solve. "
From what to build to how to build it — our platform helps you understand, plan, and solve SIH 2026 problem statements with complete insights into requirements, solution approaches, technology stacks, architecture, AI/ML, and implementation roadmaps.
Search for your problem statement, and start building your solution.
| Description: | • Background The Infrasound sensors are precision instruments designed to detect and measure low frequency atmospheric pressure waves, known as infrasound, that fall below the range of human hearing, typically under 20 Hz. These waves can travel long distances through the atmosphere and are produced by a variety of natural and human-made sources including distant Industrial explosions, volcanic eruptions, severe weather systems, meteors, rocket launches, and other energetic phenomena. Detection and analysis of these signals are important for atmospheric monitoring, geophysical research, disaster warning systems and security applications. • Description It is required to design and develop a high-sensitivity atmospheric microbarometer Infrasound sensor capable of measuring infrasonic pressure fluctuations in the frequency range of approximately 0.01 Hz to 20 Hz. The sensor should address the complete hardware architecture, including: (a).Pressure sensing mechanism. (b).Mechanical transducer design. (c).Differential pressure measurement technique. (d).Low-noise analog front-end electronics. (e).Temperature compensation. (f).Long-period pressure equalization system. (g).Environmental enclosure. (h).Wind-noise reduction interface. (i).Calibration methodology. The design should aim to detect very small pressure variations while maintaining long-term stability, low drift, and high signal fidelity. The data acquisition (digitizer) and real time waveform display & analysis software available in open market to be included to demonstrate complete functional sensor system. • Expected Solution The prototype infrasound sensor should have high sensitivity, long-term stability and low-noise signal condition to measure infrasound signals accurately. Sensor should demonstrate: (a).Detection of low-frequency pressure signals. (b).Laboratory characterization of frequency response. (c).Noise floor measurements. (d).Sensitivity estimation. (e).Stability testing. The evaluation will be conducted based on the achievement of the following parameters Attach Table Here The digitizer and data acquisition software (available in open market) for real time waveform display & analysis will be arranged by candidates themselves to demonstrate the complete functional sensor system. |
| Organization: | National Technical Research Organisation (NTRO) |
| Department: | National Technical Research Organisation (NTRO) |
| Category: | Hardware |
| Theme: | Smart Automationtd> |
| Youtube Link: | Not provided |
| Dataset Link: | Additional Information regarding PS https://drive.google.com/file/d/1rbQDRWrG-187j4hNqqc_oTiKvdjK8AzZ/view?usp=drive_link |
| Contact info: | Not provided |
The National Technical Research Organisation (NTRO) requires the design and development of a high-sensitivity atmospheric microbarometer infrasound sensor capable of measuring sub-audible pressure fluctuations in the 0.01 Hz to 20 Hz frequency band [PS]. Infrasound waves travel thousands of kilometers with minimal atmospheric attenuation, making them critical for detecting covert nuclear tests, distant industrial explosions, rocket launches, volcanic eruptions, and severe weather phenomena [KNOWN]. The proposed system addresses the full hardware lifecycle: a high-precision differential pressure transducer coupled to a mechanical long-period pressure equalization reservoir (backing cavity with a calibrated capillary flow leak) [RESEARCHED], a low-noise analog front-end (AFE) with active temperature compensation [RESEARCHED], a weather-resistant IP67 environmental enclosure [INFERENCE], and a porous-pipe wind-noise reduction spatial filter [RESEARCHED]. The sensor interfaces with an open-market, high-resolution (24-bit) digitizer and real-time waveform visualization software (e.g., Obspy / SeisComP / Python GUI) to demonstrate end-to-end signal detection, sensitivity estimation, and laboratory characterization [PS].
| Parameter | Details |
|---|---|
| PS Number | SIH26144 |
| Title | Design & Development of a High-Sensitivity Micro barometer Infrasound sensor |
| Organization | National Technical Research Organisation (NTRO) |
| Department | National Technical Research Organisation (NTRO) |
| Category | Hardware |
| Theme | Smart Automation |
| Deadline | 30 September 2026 |
| Ideas Counter | 0/500 |
To engineer a low-noise, highly stable hardware microbarometer and wind-noise mitigation interface that captures sub-pascal infrasonic waves from 0.01 Hz to 20 Hz and streams high-fidelity digital waveforms to real-time analysis software for strategic monitoring [INFERENCE].
The explicit problem statement provided by NTRO requires a functional prototype infrasound sensor covering 0.01 Hz to 20 Hz along with nine (9) mandatory hardware architectural components (a–i) and five (5) laboratory evaluation demonstrations (a–e) [PS].
| Req ID | Source Text / Aspect | Technical Interpretation | Implementation Implication | Confidence Tag |
|---|---|---|---|---|
| REQ-01 | Bandwidth: 0.01 Hz to 20 Hz | The sensor must maintain a flat frequency response across 3.3 decades of frequency down to ultra-low periods ($T = 100\text{ s}$). | Requires a mechanical acoustic high-pass filter cutoff $\le 0.005\text{ Hz}$ to prevent DC barometric saturation while passing 0.01 Hz waves [INFERENCE]. | [PS] |
| REQ-02(a) | Pressure sensing mechanism | Method to convert minute physical force/pressure changes into a measurable electrical property. | Use piezoresistive, capacitive, or MEMS strain diaphragm elements engineered for sub-pascal sensitivity [RESEARCHED]. | [PS] |
| REQ-03(b) | Mechanical transducer design | Physical housing, diaphragm geometry, and mechanical couplings for acoustic pressure waves. | Precision-machined sensing cell with dual acoustic ports (ambient vs reference chamber) [INFERENCE]. | [PS] |
| REQ-04(c) | Differential pressure measurement technique | Measuring acoustic pressure fluctuations ($P_{\text{acoustic}}$) relative to a stabilized internal reference pressure ($P_{\text{ref}}$). | Eliminates massive ambient static atmospheric pressure variations ($\sim 101,325\text{ Pa}$) to measure $\sim \text{mPa}$ fluctuations [KNOWN]. | [PS] |
| REQ-05(d) | Low-noise analog front-end electronics | Ultra-low noise amplifiers (LNAs), active filtering, and high CMRR signal conditioning. | Instrumentation amplifiers with ultralow $1/f$ noise (flicker noise at $<0.1\text{ Hz}$), high input impedance, and precision anti-aliasing filters [RESEARCHED]. | [PS] |
| REQ-06(e) | Temperature compensation | Mitigating signal drift and sensitivity changes caused by ambient ambient thermal swings. | Hardware thermistor/RTD bridge balancing or active digital temperature polynomial correction in the AFE [RESEARCHED]. | [PS] |
| REQ-07(f) | Long-period pressure equalization system | Pneumatic low-pass filter (capillary tube/micro-porous leak + reference volume) to equalize static barometric shifts. | Mechanical high-pass filter establishing the $0.01\text{ Hz}$ lower corner frequency; reference volume sealed against thermal fluctuations [RESEARCHED]. | [PS] |
| REQ-08(g) | Environmental enclosure | Rugged housing protecting fragile electronic/mechanical components against field conditions. | IP67/NEMA 4X rated enclosure with desiccant chambers, shielded bulkhead connectors, and vibration damping [INFERENCE]. | [PS] |
| REQ-09(h) | Wind-noise reduction interface | Spatial acoustic filtering to reduce turbulent boundary-layer wind noise at the sensing port. | Star-shaped porous hose array or perforated radial pipe manifold to average out incoherent wind turbulence [RESEARCHED]. | [PS] |
| REQ-10(i) | Calibration methodology | Procedure and physical apparatus to verify sensor gain, phase, and frequency response. | In-situ calibration coil/actuator or pistonphone chamber comparison against a calibrated reference standard [RESEARCHED]. | [PS] |
| REQ-11 | Digitizer & Software Integration | Integration with open-market data acquisition and waveform visualization software. | Interface AFE output to a 24-bit ADC digitizer (e.g., Earthworm/Obspy compatible) streaming seedlink/SLIP packets to real-time UI [PS]. | [PS] |
| REQ-12(a–e) | Laboratory Characterization | Prototypes must demonstrate: (a) low-freq detection, (b) response curves, (c) noise floor, (d) sensitivity, (e) stability. | Perform bench tests using sealed test chambers, signal generators, and comparison barometers [INFERENCE]. | [PS] |
| Stakeholder | Goal | Current Pain | System Need |
|---|---|---|---|
| NTRO / Defense Analysts | Monitor transboundary atmospheric events (explosions, rocket tests, yield estimation) in real time. | Commercial high-grade microbarometers (e.g., CEA MB3, Chaparral 60) are export-controlled, costly, and difficult to procure [RESEARCHED]. | Indigenously designed, ultra-low noise, high-sensitivity microbarometer with open interfacing protocols [INFERENCE]. |
| Geophysical Researchers | Study acoustic-gravity waves, volcanic plume heights, severe storm formation, and meteors [KNOWN]. | Standard weather barometers lack the frequency response ($>0.01\text{ Hz}$) and sensitivity ($<5\text{ mPa}$) needed for infrasound [KNOWN]. | Broadband flat frequency response (0.01 Hz to 20 Hz) with sub-mPa resolution [PS]. |
| Field Maintenance Engineers | Deploy long-term unattended monitoring stations in remote/harsh environments. | Temperature fluctuations cause baseline drift; wind turbulence obscures faint infrasonic signals [RESEARCHED]. | Rugged IP67 housing, thermal compensation, low power consumption ($<100\text{ mW}$), and passive wind-noise reduction [INFERENCE]. |
| Proposed Module / Feature | Supporting Requirement | Justification & Value |
|---|---|---|
| Ultra-Low Noise Differential MEMS/Piezoresistive Transducer Cell | REQ-02(a), REQ-03(b), REQ-04(c) | Directly converts pressure differences between ambient port and reference cavity into microvolt signals [PS]. |
| Capillary Tube & Reference Chamber (Mechanical Filter) | REQ-01, REQ-07(f) | Establishes $0.01\text{ Hz}$ corner frequency, equalizing slow diurnal weather pressure shifts ($\sim 1000\text{ Pa}$) [RESEARCHED]. |
| Ultra-Low $1/f$ Noise Differential Amplifier + 24-bit ADC | REQ-05(d), REQ-11 | Amplifies sub-mPa signals without flicker noise saturation; digitizes at 100 Hz sampling rate [RESEARCHED]. |
| Active Thermal Sensing & Bridge Compensation | REQ-06(e) | Eliminates temperature-induced diaphragm offset drift across $-20^\circ\text{C}$ to $+50^\circ\text{C}$ [RESEARCHED]. |
| Porous-Pipe Radial Wind-Noise Reduction System (WNRS) | REQ-09(h) | Suppresses boundary-layer turbulent wind noise by $15\text{ dB}$–$20\text{ dB}$ in the $0.1\text{ Hz}$–$4\text{ Hz}$ band [RESEARCHED]. |
| Integrated Electro-Mechanical Test / Calibration Coil | REQ-10(i), REQ-12(a–e) | Enables repeatable laboratory frequency response, sensitivity, and self-noise floor measurement [RESEARCHED]. |
| IP67 Ruggedized Enclosure with Bulkhead Acoustic Ports | REQ-08(g) | Protects internal diaphragm and high-gain electronics from humidity, dust, and mechanical strain [INFERENCE]. |
| ObsPy / Python Real-Time Waveform Display & Analysis UI | REQ-11, REQ-12(a–e) | Displays real-time filtered signals, Power Spectral Density (PSD), self-noise curves, and event logs [PS]. |
| Data Type | Purpose | Ideal Real-World Source | Hackathon Substitute | Access Method | Availability | Privacy Sensitivity | Confidence |
|---|---|---|---|---|---|---|---|
| Real-Time Pressure Waveform (Raw) | Primary sensor output digitized at 100 Hz | 24-bit ADC stream from microbarometer AFE | USB/SPI stream from prototype ADC module | Serial/SPI / TCP Stream | Real-time generate | None (Acoustic data) | [PS] |
| Reference Infrasound Datasets | Algorithm validation & waveform matching | CTBTO IMS Infrasound Network / IRIS DMC [RESEARCHED] | Public IRIS Wilbur / ObsPy infrasound data repository [RESEARCHED] | ObsPy Python API download | Fully Public | None | [RESEARCHED] |
| Ambient Thermal & Barometric Data | Baseline drift subtraction and compensation | Precision BMP390 / BME280 digital barometer | On-board I2C environmental sensor | I2C Bus | Public / Standard component | None | [KNOWN] |
| Calibration Signal Data | Frequency response characterization | Pistonphone / Laser interferometer reference [RESEARCHED] | Known sine/step voltage driving internal actuator coil | Audio DAC / Function Generator | Generated in Lab | None | [INFERENCE] |
| Solution Name | System Overview | Strengths | Weaknesses | Gap vs Proposed System | Source | Confidence |
|---|---|---|---|---|---|---|
| CEA/DASE MB3 Microbarometer | Gold standard CTBTO IMS infrasound sensor using linear variable differential transformer (LVDT) capsule [RESEARCHED]. | Ultra-low noise ($<1\text{ mPa}$), $0.01\text{–}27\text{ Hz}$ response, internal test coil [RESEARCHED]. | Extremely expensive ($>$10,000$), ITAR/export restricted, heavy [RESEARCHED]. | Propose a low-cost, open-hardware piezoresistive/MEMS architecture accessible to domestic defense/research teams [INFERENCE]. | Acoustical Society / CTBTO | [RESEARCHED] |
| Chaparral Physics Model 60 / 64S | Precision differential pressure microbarometer widely used in academic geophysical arrays [RESEARCHED]. | Wide dynamic range ($120\text{ dB}$), flat response $0.01\text{–}50\text{ Hz}$, low power ($<30\text{ mW}$) [RESEARCHED]. | Proprietary closed hardware, proprietary calibration setups [RESEARCHED]. | Propose fully open hardware design with integrated USB/Ethernet digitizer and open-source software integration [INFERENCE]. | Sandia National Labs Report | [RESEARCHED] |
| Infra-NMT / KNMI Mini-MB | Low-cost academic infrasound sensors using commercial differential piezoresistive MEMS transducers [RESEARCHED]. | Low cost ($<$300$), simple capillary mechanical high-pass filter, low power [RESEARCHED]. | Thermal drift under outdoor conditions, lacks integrated self-calibration hardware [RESEARCHED]. | Incorporates active dual-stage thermal stabilization and integrated electro-mechanical calibration coil [INFERENCE]. | Copernicus AMT Journal | [RESEARCHED] |
Approach 1 (Piezoresistive Differential MEMS with Pneumatic Capillary Filter & Chopper AFE) is selected [INFERENCE].
[ Atmospheric Acoustic Input ]
│
▼
┌────────────────────────────────────────────────────────────────────────┐
│ MECHANICAL / ACOUSTIC FRONT-END │
│ │
│ Ambient Port ──► [ Porous Pipe Wind-Noise Reduction System (WNRS) ] │
│ │ │
│ ├──────────────────────────────┐ │
│ ▼ ▼ │
│ ┌──────────────────┐ ┌────────────────────┐ │
│ │ Port A (Sensing) │ │ Capillary Flow Leak│ │
│ └─────────┬────────┘ └─────────┬──────────┘ │
│ │ ▼ │
│ │ ┌────────────────────┐ │
│ │ │ Thermal Insulated │ │
│ │ │ Reference Chamber │ │
│ │ │ (500 mL Cavity) │ │
│ │ └─────────┬──────────┘ │
│ │ ▼ │
│ │ ┌────────────────────┐ │
│ │ │ Port B (Reference) │ │
│ │ └─────────┬──────────┘ │
│ │ │ │
│ ▼ ▼ │
│ ┌──────────────────────────────────────────┐ │
│ │ Piezoresistive Differential Strain Cell │ │
│ └────────────────────┬─────────────────────┘ │
└────────────────────────────────────────┼───────────────────────────────┘
│ Microvolt Differential Signal
▼
┌────────────────────────────────────────────────────────────────────────┐
│ LOW-NOISE ANALOG FRONT-END (AFE) │
│ │
│ ┌─────────────────────────┐ ┌──────────────────────────────────┐ │
│ │ Precision Low-Drift │ ──► │ Zero-Drift Chopper Instrument. │ │
│ │ Voltage Reference (<5ppm│ │ Amplifier (ADA4522 / LTC2057) │ │
│ └─────────────────────────┘ └────────────────┬─────────────────┘ │
│ ▼ │
│ ┌─────────────────────────┐ ┌──────────────────────────────────┐ │
│ │ Thermal Sensor (PT1000) │ ──► │ Active Low-Pass Anti-Aliasing │ │
│ │ Signal Conditioning │ │ Filter (Sallen-Key fc=25 Hz) │ │
│ └─────────────────────────┘ └────────────────┬─────────────────┘ │
└────────────────────────────────────────┼───────────────────────────────┘
│ Low-Noise Analog Volts
▼
┌────────────────────────────────────────────────────────────────────────┐
│ DATA ACQUISITION & DIGITIZER HARDWARE │
│ │
│ ┌──────────────────────────────────────────────────────────────────┐ │
│ │ 24-Bit Delta-Sigma ADC (ADS1220 / ADS127L01 @ 100 SPS) │ │
│ └────────────────────────────────┬─────────────────────────────────┘ │
│ │ SPI / UART │
│ ▼ │
│ ┌──────────────────────────────────────────────────────────────────┐ │
│ │ Microcontroller / SBC (ESP32-S3 / STM3238 / Raspberry Pi) │ │
│ │ - Precision NTP/GPS Timestamping │ │
│ │ - SeedLink Protocol / Serial Packetizer │ │
│ └────────────────────────────────┬─────────────────────────────────┘ │
└────────────────────────────────────────┼───────────────────────────────┘
│ USB / Ethernet / Wi-Fi
▼
┌────────────────────────────────────────────────────────────────────────┐
│ OPEN MARKET WAVEFORM DISPLAY & ANALYSIS SOFTWARE │
│ │
│ ┌─────────────────────────┐ ┌──────────────────────────────────┐ │
│ │ Real-Time Waveform GUI │ │ ObsPy / Python Signal Processing │ │
│ │ (PlotJuggler / SeisComP)│ ──► │ - Bandpass Filter (0.01 - 20 Hz) │ │
│ │ Stream Plotting │ │ - PSD & Self-Noise Floor Curve │ │
│ └─────────────────────────┘ │ - STA/LTA Infrasound Trigger │ │
│ └──────────────────────────────────┘ │
└────────────────────────────────────────────────────────────────────────┘
| Layer | Selected Technology | Why | Alternative | Why Rejected |
|---|---|---|---|---|
| Sensing Transducer | Amphenol NPC-1210 / AllSensors DLVR Differential MEMS | High sensitivity ($\pm 125\text{ Pa}$ dynamic range), dual port, low noise [RESEARCHED]. | Honeywell TruStability HSC | Higher self-noise floor in ultra-low frequency band [RESEARCHED]. |
| Acoustic Mechanical Filter | Precision Glass Micro-Capillary ($d=0.1\text{–}0.3\text{ mm}$) + $0.5\text{ L}$ Chamber | Establishes physical pneumatic low-pass cutoff at $f_c = 0.01\text{ Hz}$ [RESEARCHED]. | Porous Sintered Metal Disc | Unpredictable pore distribution makes exact $0.01\text{ Hz}$ tuning difficult [RESEARCHED]. |
| Analog Amplifier (AFE) | ADA4522 / LTC2057 Zero-Drift Chopper Op-Amp | Near-zero $1/f$ flicker noise at $0.01\text{ Hz}$, $<5\text{ nV}/\sqrt{\text{Hz}}$ voltage noise [RESEARCHED]. | Standard NE5532 / TL072 | High flicker noise satualtion below $1\text{ Hz}$ ruins infrasound signal [KNOWN]. |
| ADC / Digitizer Hardware | ADS1220 / ADS127L01 24-bit Delta-Sigma ADC | 24-bit resolution, low noise ($<1\text{ }\mu\text{V}_{\text{p-p}}$), customizable sampling rate ($100\text{ SPS}$) [RESEARCHED]. | 16-bit ADS1115 | Insufficient dynamic range to capture $1\text{ mPa}$ to $100\text{ Pa}$ simultaneously ($>100\text{ dB}$ needed) [INFERENCE]. |
| Embedded Controller | ESP32-S3 / STM32F4 + GPS Module | Integrated SPI/I2C, low power, precision hardware timers, hardware USB/UART [INFERENCE]. | Arduino Uno / ATmega328P | 8-bit architecture lacks memory and speed for 24-bit digital filtering & SeedLink streaming [INFERENCE]. |
| Wind-Noise Reduction | 4-Arm Radial Porous Soaker Hose Array | Proven spatial averaging technique for outdoor turbulent noise mitigation [RESEARCHED]. | Solid Plastic Dome Cover | Insufficient spatial averaging for low-frequency wind gusts [RESEARCHED]. |
| Waveform Software | Python ObsPy + PlotJuggler / SeisComP | Open-source geophysical standard for infrasound/seismic waveform display & analysis [RESEARCHED]. | Proprietary LabVIEW | High licensing cost; incompatible with open-market SIH guidelines [INFERENCE]. |
┌────────────────────────────────────────────────────────────────────────┐
│ SENSOR EMBEDDED FIRMWARE │
│ │
│ ┌──────────────────────┐ ┌───────────────────────────────────┐ │
│ │ 24-Bit ADC Samples │ ───► │ Circular Ring Buffer in RAM │ │
│ │ (100 Hz Raw Stream) │ │ (30 Seconds Buffer) │ │
│ └──────────────────────┘ └─────────────────┬─────────────────┘ │
│ │ │
│ ▼ │
│ ┌───────────────────────────────────┐ │
│ │ MicroSD Card Local Storage │ │
│ │ (mini-SEED Binary File Format) │ │
│ └─────────────────┬─────────────────┘ │
└───────────────────────────────────────────────────┼────────────────────┘
│ SPI / SDIO
▼
┌────────────────────────────────────────────────────────────────────────┐
│ NETWORK TRANSMISSION & SYNCHRONIZATION │
│ │
│ ┌───────────────────────────────────┐ │
│ │ Connection Status Detector │ │
│ └─────────────────┬─────────────────┘ │
│ │ │
│ ┌─────────────────────────┴────────────────────────┐ │
│ ▼ ▼ │
│ [ ONLINE MODE ] [ OFFLINE MODE ] │
│ - Stream SeedLink TCP Packets to Server - Log locally │
│ - Sync NTP Time Server - Retain SD files │
│ - Real-time Plotting - Auto-backfill │
└────────────────────────────────────────────────────────────────────────┘
┌─────────────────────────────────────────────────────────────────────────┐
│ HACKATHON MVP SCOPE (MUST BUILD) │
│ │
│ [1] Physical Sensor Prototype │
│ - Piezoresistive differential pressure cell with capillary leak │
│ - Thermally insulated reference chamber │
│ - Low-noise AFE PCB with chopper op-amp & 24-bit ADC │
│ │
│ [2] Wind-Noise Reduction Interface (WNRS) │
│ - Miniaturized 4-port porous tube spatial filter │
│ │
│ [3] Data Acquisition & Interface │
│ - Microcontroller running 100 Hz sampler firmware │
│ - USB/Serial data streaming protocol │
│ │
│ [4] Open Software Display & Analysis GUI │
│ - Real-time waveform display (ObsPy / Python GUI) │
│ - Bandpass filter (0.01 Hz - 20 Hz) │
│ - Power Spectral Density (PSD) plot & Noise Floor Calculation │
└─────────────────────────────────────────────────────────────────────────┘
│
│ OUT OF SCOPE FOR HACKATHON
▼
┌─────────────────────────────────────────────────────────────────────────┐
│ PRODUCTION / FUTURE EXTENSIONS │
│ │
│ - Multi-station array beamforming & direction-of-arrival (DOA) │
│ - Hermetically sealed titanium housing with MIL-SPEC connectors │
│ - Satellite / Iridium direct uplink hardware │
│ - ISO/IEC 17025 accredited NPL calibration certificate │
└─────────────────────────────────────────────────────────────────────────┘
Demonstrating ultra-low frequency infrasound ($0.01\text{ Hz}$) live inside a hackathon hall is challenging due to ambient noise and lack of large pressure chambers. The team will execute a 3-Tier Simulated / Physical Demonstration:
┌────────────────────────────────────────────────────────────────────────┐
│ LIVE HACKATHON DEMO STRATEGY │
│ │
│ TIER 1: Physical Infrasound Signal Generation (In-Person Hardware) │
│ - Mechanical Syringe / Sealed Accordion Bellows Test rig: │
│ Slow manual/motorized compression creates 0.1 Hz - 1 Hz pressure │
│ pulses (~1 - 5 Pa) inside a sealed 2L acrylic test box. │
│ - Real-time sensor response visible on GUI instantly. │
│ │
│ TIER 2: Self-Noise Floor & Baseline Stability Test │
│ - Cap the sensor ports in an insulated chamber. │
│ - Live compute PSD (Power Spectral Density) showing sub-mPa self-noise│
│ floor across 0.01 Hz to 20 Hz. │
│ │
│ TIER 3: Open-Market Software & Reference Injection │
│ - Inject historical public infrasound event (e.g., Tonga eruption / │
│ rocket launch) into open-market digitizer pipeline to demonstrate │
│ waveform display, filtering, and event detection capability. │
└────────────────────────────────────────────────────────────────────────┘
Target Deadline: 30 September 2026 [PS].
┌────────────────────────────────────────────────────────────────────────┐
│ IMPLEMENTATION ROADMAP (Sized to 30 September 2026) │
│ │
│ PHASE 1: Acoustic Physics & Circuit Design [Oct 2025 - Dec 2025] │
│ ├─ Capillary leak dimensioning & reference cavity CAD modeling │
│ └─ Schematics & PCB layout for Chopper AFE & 24-bit ADC │
│ │
│ PHASE 2: Hardware Prototyping & Mechanical Assembly [Jan 2026 - Mar 2026]│
│ ├─ Fabrication of reference chamber & CNC/3D printed enclosure │
│ ├─ PCB assembly, soldering, and low-noise shielding │
│ └─ Microcontroller firmware (100 Hz sampling & mini-SEED logging) │
│ │
│ PHASE 3: Software Integration & Bench Calibration [Apr 2026 - Jun 2026]│
│ ├─ ObsPy Python real-time GUI & SeedLink receiver development │
│ ├─ Syringe/bellows low-frequency pressure pulse testing │
│ └─ Frequency response & self-noise floor estimation │
│ │
│ PHASE 4: Outdoor Field Testing & WNRS Validation [Jul 2026 - Aug 2026] │
│ ├─ Deployment with 4-arm porous pipe WNRS array in outdoor environment │
│ └─ Temperature drift verification across outdoor day/night cycle │
│ │
│ PHASE 5: Hardening, Documentation & Final Presentation [Sep 2026] │
│ └─ Final system dossier, video demonstration, and SIH submission │
└────────────────────────────────────────────────────────────────────────┘
| Test Category | Target Parameter / Metric | Test Procedure | Pass / Fail Criteria |
|---|---|---|---|
| Frequency Response | Flat response over $0.01\text{ Hz}$ to $20\text{ Hz}$ ($\pm 3\text{ dB}$) | Sweep low-frequency acoustic excitation in sealed chamber using function generator | Magnitude response remains flat down to $0.01\text{ Hz}$ ($\pm 3\text{ dB}$) [INFERENCE]. |
| Self-Noise Floor | $< 2\text{ mPa RMS}$ in $0.1\text{–}2\text{ Hz}$ band | Cap both sensor ports in thermally stable chamber; record 1 hour background noise | PSD self-noise floor below CTBTO Low Noise Model curve [RESEARCHED]. |
| Sensitivity | Nominal $20\text{ mV/Pa}$ (or digital equivalent) | Apply reference pressure step ($\Delta P = 1.0\text{ Pa}$) using micro-calibrator | Measured voltage/digital count matches calculated transfer function within $\pm 5%$ [INFERENCE]. |
| Thermal Drift | Baseline drift $< 10\text{ mPa}/^\circ\text{C}$ | Subject capped sensor to thermal ramp ($-10^\circ\text{C}$ to $+40^\circ\text{C}$) in chamber | Active compensation limits baseline output drift to $<10\text{ mPa}/^\circ\text{C}$ [RESEARCHED]. |
| Wind-Noise Mitigation | $> 15\text{ dB}$ noise reduction at $1\text{ Hz}$ | Compare outdoor noise spectrum with bare port vs Porous Hose WNRS | WNRS demonstrates $\ge 15\text{ dB}$ attenuation of turbulent wind spectrum [RESEARCHED]. |
| Risk Description | Likelihood | Impact | Severity | Mitigation Strategy |
|---|---|---|---|---|
| Flicker ($1/f$) Noise Saturation: Low-frequency electronic noise overwhelms $0.01\text{ Hz}$ infrasound signals. | Medium | High | High | Use zero-drift chopper operational amplifiers (ADA4522) and ultralow-drift voltage references [RESEARCHED]. |
| Thermal Pressure Drift: Temperature changes inside reference cavity mimic pressure waves. | High | High | High | Wrap reference cavity in thermal insulation foam and employ active differential thermistor bridge correction [RESEARCHED]. |
| Capillary Blockage: Dust or moisture clogs micro-capillary leak tube, destroying $0.01\text{ Hz}$ cutoff. | Medium | Medium | Medium | Install $0.5\text{ }\mu\text{m}$ PTFE hydrophobic air filters at capillary inlet ports [INFERENCE]. |
| Enclosure Acoustic Leakage: Unsealed housing seams create spurious acoustic low-pass filtering. | High | High | High | Use O-ring sealed IP67 aluminum enclosure with metal bulkhead connectors [INFERENCE]. |
| ADC Quantization Noise: Inadequate ADC bit depth hides sub-mPa signals. | Low | High | Medium | Use true 24-bit Delta-Sigma ADC with low-noise PGA [RESEARCHED]. |
| Component / Layer | Estimated Cost (INR) | Sourcing Strategy |
|---|---|---|
| Differential MEMS Transducer (Amphenol NPC-1210 / AllSensors) | ₹4,500 | Commercial Electronics Importer / Digikey |
| Custom AFE PCB (Chopper Op-Amps, ADS1220 ADC, Passive Filter) | ₹3,500 | JLCPCB / PCBWay Prototype Order |
| Mechanical Cavity & Micro-Capillary Glass Tube | ₹2,500 | Scientific Glassware / Precision Machine Shop |
| ESP32-S3 + GPS Board + MicroSD Module | ₹2,000 | Local Electronics Vendor |
| IP67 Rugged Enclosure & Bulkhead Fittings | ₹2,500 | Standard Industrial Hardware |
| Porous Tube WNRS Array (Soaker Hoses + Manifold) | ₹1,500 | Local Agricultural / Hardware Store |
| Total Hackathon Prototype Cost | ₹16,500 | Fully within student project budgets |
| Parameter | Generic Hackathon Submission | Proposed NTRO Microbarometer System |
|---|---|---|
| Sensing Approach | Uses off-the-shelf digital barometers (BMP280/390) which fail below $1\text{ Hz}$ due to noise [KNOWN]. | Precision differential pressure transducer with calibrated pneumatic micro-capillary filter ($f_c=0.01\text{ Hz}$) [RESEARCHED]. |
| Low-Noise Design | Standard general-purpose Op-Amps dominated by $1/f$ flicker noise [KNOWN]. | Zero-drift chopper-stabilized instrumentation AFE with $<2\text{ mPa}$ self-noise floor [RESEARCHED]. |
| Environmental Mitigation | Naked sensor port exposed to outdoor wind gusts. | Integrated star-shaped Porous-Pipe Wind-Noise Reduction System (WNRS) [RESEARCHED]. |
| Software & Compliance | Standalone serial plotter widget. | Full SeedLink data streaming into open-source standard geophysical software (ObsPy) [RESEARCHED]. |
[ASSUMPTION] Commercial differential MEMS pressure sensors (e.g., Amphenol NPC-1210 / AllSensors DLVR) can be procured by student teams within India in under 3 weeks.[ASSUMPTION] A $0.5\text{ L}$ sealed acrylic/aluminum reference cavity combined with a $0.2\text{ mm}$ glass capillary tube provides a stable mechanical high-pass corner frequency near $0.01\text{ Hz}$.[ASSUMPTION] A motorized syringe or bellows assembly in a sealed container provides a sufficient low-frequency physical pressure signal for live hackathon jury demonstrations.[NEEDS VALIDATION] Verify the exact noise floor parameters specified in the NTRO PS attached table (Google Drive file) against the standard CTBTO Low Noise Model.[NEEDS VALIDATION] Determine whether the evaluation committee requires RS-232, Ethernet, or USB physical interfaces for open-market digitizer integration.[NEEDS VALIDATION] Test whether local agricultural porous soaker hose materials provide adequate spatial averaging impedance comparable to certified CTBTO WNRS porous pipes.Proceed with the development of Approach 1 (Piezoresistive Differential MEMS with Pneumatic Capillary Filter & Chopper AFE). It directly satisfies every requirement of SIH26144, achieves physical differential sensing down to $0.01\text{ Hz}$, and avoids the severe $1/f$ noise and dynamic range saturation flaws of generic digital barometer approaches [INFERENCE].
Sourcing high-sensitivity, low-range differential pressure transducers ($\pm 125\text{ Pa}$ or $\pm 250\text{ Pa}$ full scale) with exposed dual differential ports [INFERENCE].
Flicker noise ($1/f$) and thermal drift overwhelming the low-frequency ($0.01\text{ Hz}$) pressure signal [RESEARCHED].
Accurately calibrating the acoustic micro-capillary leak to achieve an exact $0.01\text{ Hz}$ ($T = 100\text{ s}$) mechanical cutoff frequency without a metrological pressure chamber [RESEARCHED].
85 / 100 Reasoning: Highly feasible for a multi-disciplinary student team combining electronics, mechanical/fluid mechanics, and Python software skills. The hardware components are standard, though low-noise AFE layout and pneumatic capillary tuning require careful engineering [INFERENCE].
HIGH (Supported by established academic literature on piezoresistive microbarometers from KNMI, Infra-NMT, and CTBTO IMS standards) [RESEARCHED].
Title: Implementation, Characterization, and Evaluation of an Inexpensive Low-Power Low-Noise Infrasound Sensor Based on a Micromachined Differential Pressure Transducer and a Mechanical Filter
Title: The INFRA-EAR: a low-cost mobile multidisciplinary measurement platform for monitoring geophysical parameters
Title: Infrasound sensors and their calibration at low frequency
Title: Chaparral 64S Infrasound Sensor Type Approval Evaluation Report
What we think about this platform, and how it can help people solve SIH problems.
" 30M+ Google Gemini tokens went into researching, analyzing, and understanding all 233 SIH problem statements to make them easier to explore and solve. "
" The platform makes SIH problem statements much easier to understand. Having everything from the problem details to the procedure in one place. "
" Oh, you got ads? Well, we need to make money too! But, you can use our platform to help you win SIH and take home the prize money. "
Get in touch if you need help bringing your ideas to life, or simply have an interesting idea you'd like to talk through. I'm always open to a conversation and exploring new possibilities together.