" 30M+ Google Gemini tokens went into researching, analyzing, and understanding all 233 SIH problem statements to make them easier to explore and solve. "
From what to build to how to build it — our platform helps you understand, plan, and solve SIH 2026 problem statements with complete insights into requirements, solution approaches, technology stacks, architecture, AI/ML, and implementation roadmaps.
Search for your problem statement, and start building your solution.
| Description: | Background: Law enforcement agencies currently lack a reliable, portable, non-invasive method to detect recent drug consumption in the field, comparable to a breathalyzer used for alcohol detection. Existing methods - urine or blood testing - are invasive, time-consuming, and unsuitable for rapid field screening. Breath, saliva, and sweat are known to contain biomarkers correlating with recent drug use, but no indigenous, field-ready device presently exists to read them reliably. Description: Participants are to design and build a prototype handheld device capable of detecting the presence of common narcotic substances (such as opioids, cannabis, and synthetic drugs) through breath-sample analysis, using electrochemical or equivalent sensing technology. The device should: Provide a rapid, near real-time result at the point of testing. Be portable and operable by field personnel with minimal training. Indicate a clear positive / negative / inconclusive result. Be built using accessible sensor components suitable for a working prototype demonstration. Expected Deliverables: A working hardware prototype capable of demonstrating breath-sample analysis and producing a result, along with a brief technical explanation of the sensing method used and its accuracy on a provided or self-generated test set. Note to Participants: This is a proof-of-concept prototype intended to demonstrate technical feasibility. It is not expected to be a forensically validated or field-certified device at the end of the hackathon. |
| Organization: | Ministry of Home Affairs |
| Department: | Narcotics Control Bureau |
| Category: | Hardware |
| Theme: | MedTech / BioTech / HealthTechtd> |
| Youtube Link: | Not provided |
| Dataset Link: | Not provided |
| Contact info: | Not provided |
Law enforcement agencies, particularly the Narcotics Control Bureau (NCB) under the Ministry of Home Affairs (MHA), face a major operational bottleneck due to the absence of rapid, non-invasive, point-of-testing field screening tools for illicit drug consumption [PS]. Existing biological screening techniques rely on urine or blood samples, which require invasive collection procedures, specialized personnel, sanitary facilities, and extended laboratory analysis times [PS]. This dossier proposes NarkoBreath, an indigenous, handheld, electrochemical breath-analysis prototype designed for rapid field screening of narcotics (including cannabinoids, opioids, and synthetic drugs) [PS, INFERENCE]. The system integrates a micro-condensation exhaled breath condensate (EBC) aerosol trap, disposable screen-printed carbon electrodes (SPCE) functionalized with electroactive receptor materials, a low-power potentiostat analog front-end (TI LMP91000), and an ESP32 micro-controller [RESEARCHED, ASSUMPTION]. Utilizing Differential Pulse Voltammetry (DPV) signal analysis coupled with lightweight edge pattern classification, the device delivers a deterministic "Positive / Negative / Inconclusive" determination in under 90 seconds [PS, INFERENCE]. Results are displayed on an onboard OLED screen and transmitted securely via Bluetooth Low Energy (BLE) to an encrypted mobile application for tamper-evident digital chain-of-custody logging [INFERENCE, ASSUMPTION].
| Field | Detail |
|---|---|
| Problem Statement ID | SIH26230 [PS] |
| Title | Breath-Based Detection Device for Drug Consumption [PS] |
| Organization | Ministry of Home Affairs (MHA) [PS] |
| Department | Narcotics Control Bureau (NCB) [PS] |
| Category | Hardware [PS] |
| Theme | MedTech / BioTech / HealthTech [PS] |
| Deadline | 30 September 2026 [PS] |
| Ideas Counter | 0/500 [PS] |
To engineer a portable, low-cost, handheld hardware prototype capable of capturing exhaled breath aerosols, performing electrochemical voltammetric analysis on disposable sensor strips, and generating an immediate, reliable, field-operable tri-state classification for common narcotics with digital chain-of-custody verification [PS, INFERENCE].
REQ-1: Target Domain & Authority
REQ-2: Sample Matrix
REQ-3: Target Substance Spectrum
REQ-4: Core Technology Mechanism
REQ-5: Output & Tri-State Result
REQ-6: Portability & Usability
REQ-7: Hackathon Component Accessibility
REQ-8: Scope & Proof-of-Concept Boundary
| Stakeholder | Goal | Current Pain | System Need |
|---|---|---|---|
| NCB Field Officers / Highway Police | Rapid roadside screening of suspected impaired drivers or individuals [PS, INFERENCE]. | Urine/blood sampling requires medical personnel, hospital transport, and hours of delay; current field kits only test physical powders [PS, KNOWN]. | Handheld, one-touch device providing instant (< 90 sec) clear screen results with zero physical fluid contact [PS, INFERENCE]. |
| Forensic Science Laboratories (FSL) | High-confidence confirmatory analysis without sample backlog overcrowding [RESEARCHED]. | Unfiltered, unscreened suspect samples flood lab GC-MS facilities, increasing turnaround times to months [RESEARCHED]. | Pre-filtered digital logging where only "Positive" field-screened individuals proceed to statutory confirmatory testing [INFERENCE]. |
| Accused / Citizens | Fair, non-invasive, non-humiliating screening process during traffic stops [INFERENCE]. | Invasive urine collection in public settings compromises dignity and civil rights [PS, INFERENCE]. | Non-invasive, single-use hygienic mouthpiece breath test completed in seconds [PS, INFERENCE]. |
| NCB Administrative Command | Real-time geospatial tracking of drug consumption hotspots and officer activity [INFERENCE]. | Paper-based field reports suffer from data loss, lack of geo-tagging, and risk of chain-of-custody tampering [INFERENCE]. | Encrypted cloud synchronization with GPS coordinates, timestamp, and immutable device audit logs [INFERENCE, ASSUMPTION]. |
| Proposed System Feature | Justifying Requirement | Implementation Component |
|---|---|---|
| Thermoelectric Micro-Condenser Intake | REQ-2 (Breath Sample Analysis) [PS] | Peltier-cooled micro-channel mouthpiece trapping aerosol droplets [RESEARCHED]. |
| Multi-Voltammetric Scan Controller | REQ-3 (Opioids, Cannabis, Synthetic Drugs) [PS] & REQ-4 (Electrochemical Sensing) [PS] | TI LMP91000 AFE performing Differential Pulse Voltammetry (DPV) sweeps [RESEARCHED]. |
| Screen-Printed Carbon Electrode Interface | REQ-4 (Electrochemical Sensing) [PS] & REQ-7 (Accessible Components) [PS] | Standard 3-electrode SPCE strip socket (Working, Reference, Counter) [RESEARCHED]. |
| Tri-State Result Processing Engine | REQ-5 (Rapid Clear Positive/Negative/Inconclusive) [PS] | Edge peak-detection algorithm evaluating Signal-to-Noise Ratio (SNR) and threshold limits [INFERENCE]. |
| OLED Display & Tri-Color LED Indicators | REQ-5 (Clear Result) [PS] & REQ-6 (Minimal Training) [PS] | 1.3" I2C SH1106 OLED + RGB Status LED driven directly by ESP32 GPIOs [ASSUMPTION]. |
| BLE Mobile App & Chain-of-Custody Logger | REQ-1 (Law Enforcement Deployment) [PS] | Flutter Mobile App storing AES-256 encrypted test records with GPS/timestamp [INFERENCE, ASSUMPTION]. |
| Non-Controlled Chemical Demonstration Set | REQ-8 (Proof-of-Concept / Test Set Accuracy) [PS] | Test set using Acetaminophen, Ascorbic Acid, and Caffeine as electroactive surrogates [RESEARCHED, ASSUMPTION]. |
| Data Type | Purpose | Ideal Real-World Source | Hackathon Substitute | Access Method | Availability | Privacy Sensitivity | Confidence |
|---|---|---|---|---|---|---|---|
| Narcotics Voltammetric Response Curves | Train peak classification algorithms for THC, Morphine, Amphetamines. | Standard reference chemicals in forensic toxicology labs (NCB/FSL) [RESEARCHED]. | Differential Pulse Voltammetry (DPV) curves generated using electroactive surrogates (Acetaminophen, Ascorbic Acid, Dopamine) [RESEARCHED, ASSUMPTION]. | Laboratory collection via custom potentiostat bench setup. | Readily available via self-generation [ASSUMPTION]. | Low (Synthetic chemical standards) [KNOWN]. | [RESEARCHED] |
| Breath Condensate Flow Metrics | Validate breath volume, flow rate, and collection time. | Clinical spirometry & EBC breath collection studies [RESEARCHED]. | Airflow sensor (MPX5010DP pressure transducer) breath flow logs [RESEARCHED, ASSUMPTION]. | Microcontroller ADC serial stream logging. | Self-generated during hardware calibration. | Low [KNOWN]. | [RESEARCHED] |
| Interferent Voltammetric Profiles | Prevent false positives from alcohol, nicotine, caffeine, menthol. | Chemical databases (PubChem, NIST Electrochemical Database) [RESEARCHED]. | Empirical DPV sweeps of coffee, tobacco extract, and mouthwash on SPCE strips [RESEARCHED, ASSUMPTION]. | Direct sensor measurement and literature lookup. | Public literature / empirical lab testing. | Low [KNOWN]. | [RESEARCHED] |
| Operator Field Logs & Metadata | Maintain chain of custody (GPS, timestamp, Officer ID, Result). | NCB National Integrated Database [INFERENCE]. | SQLite local database in mobile app synced to Firebase / PostgreSQL backend [ASSUMPTION]. | BLE JSON payload parsing. | Open source simulation. | High (Personal identification data) [INFERENCE]. | [INFERENCE] |
+---------------------------------------------------------------------------------------------------+
| CANDIDATE ARCHITECTURAL APPROACHES |
+------------------------------------+--------------------------------+-----------------------------+
| Approach 1: MOS Gas Sensor Array | Approach 2: Handheld Raman | Approach 3 (Selected): EBC |
| (Metal-Oxide Semiconductors) | Spectrometer Prototype | Electrochemical Voltammetry |
+------------------------------------+--------------------------------+-----------------------------+
| • Heating element (300-400°C) | • 785nm Laser Diode excitation | • Peltier EBC Condensor |
| • VOC resistance changes | • SERS substrate cartridge | • Disposable SPCE Strips |
| • Pattern recognition array | • Optical spectrometer sensor | • TI LMP91000 Potentiostat |
| • High false positives from alcohol| • High cost (>₹2,00,000) | • DPV Peak Analysis |
| • Incapable of non-volatiles | • Laser hazard in field | • Rapid, Low-Cost, Precise |
+------------------------------------+--------------------------------+-----------------------------+
| Evaluation Criterion | Approach 1: MOS Gas Sensor Array | Approach 2: SERS Raman Optical Sensing | Approach 3: EBC Micro-Condenser + Electrochemical Voltammetry (SELECTED) |
|---|---|---|---|
| Problem Fit | Poor (Low selectivity for heavy non-volatile drug molecules) [RESEARCHED]. | High (High molecular specificity) [RESEARCHED]. | High (Excellent sensitivity for dissolved ionic/electroactive analytes) [RESEARCHED]. |
| Accuracy Potential | Low (Cross-sensitivity to ethanol, acetone, humidity) [RESEARCHED]. | Very High (Vibrational fingerprint matching) [RESEARCHED]. | High (Distinct oxidation peak potentials $E_{peak}$ via DPV) [RESEARCHED]. |
| Data Requirements | Medium (Multi-sensor array response signatures) [INFERENCE]. | High (Spectral reference library matching) [RESEARCHED]. | Medium (Voltammetric current-voltage curves) [RESEARCHED]. |
| Hardware Complexity | Low (Simple analog resistance reading) [KNOWN]. | Extreme (Laser optics, spectrograph, fine alignment) [RESEARCHED]. | Moderate (Potentiostat circuit, micro-fluidic trap) [RESEARCHED]. |
| Explainability | Low (Black-box multi-gas neural network) [INFERENCE]. | High (Direct spectral peak identification) [RESEARCHED]. | High (Clear thermodynamic redox peak potential analysis) [RESEARCHED]. |
| Cost Per Unit | Very Low (< ₹3,000) [INFERENCE]. | Extreme (> ₹2,00,000) [RESEARCHED]. | Low (₹4,000–₹6,000 device; ₹30/strip consumable) [INFERENCE, ASSUMPTION]. |
| Scalability | High [INFERENCE]. | Low (High precision manufacturing required) [RESEARCHED]. | High (Mass-produced screen-printed electrodes) [RESEARCHED]. |
| Hackathon Feasibility | High [INFERENCE]. | Very Low (Cannot build optical spectrometer in hackathon) [INFERENCE]. | High (COTS components: ESP32 + LMP91000 + SPCE) [RESEARCHED, ASSUMPTION]. |
| Production Feasibility | Low (Fails legal validation due to false positives) [INFERENCE]. | Moderate [RESEARCHED]. | High (Standard medical biosensor model like glucometers) [RESEARCHED]. |
| Primary Risks | High false positive rate [RESEARCHED]. | Optical misalignment, battery drain, laser safety hazards [RESEARCHED]. | Condensation rate variability in dry environments [RESEARCHED]. |
Approach 3: Exhaled Breath Condensate (EBC) Micro-Condensing Collection paired with Multi-Channel Electrochemical Voltammetry.
Illicit drugs (THC, Opioids, Amphetamines) have low vapor pressures and exist in exhaled breath primarily trapped inside microscopic fluid aerosols ($0.5\text{--}5,\mu\text{m}$) originating from the deep lung surface lining fluid [RESEARCHED].
+---------------------------------------------------------------------------------------------------+
| 1. PHYSICAL INGESTION LAYER |
| +---------------------------+ +-------------------------------+ +---------------------------+ |
| | Single-Use Mouthpiece | | Peltier Condensation Chamber | | SPCE Sensor Socket | |
| | (Anti-Backflow Valve) | | (Aerosol Liquid Trap Module) | | (Working/Ref/Counter) | |
| +-------------+-------------+ +---------------+---------------+ +-------------+-------------+ |
+----------------|--------------------------------|--------------------------------|----------------+
| | |
v v v
+---------------------------------------------------------------------------------------------------+
| 2. ANALOG FRONT-END & SENSOR LAYER |
| +---------------------------------------------------------------------------------------------+ |
| | Texas Instruments LMP91000 Programmable Potentiostat AFE | |
| | (Transimpedance Amplifier + Working/Reference/Counter Electrode Driving Circuit) | |
| +----------------------------------------------+----------------------------------------------+ |
| +----------------------------------------------+----------------------------------------------+ |
| | Auxiliary Sensors: SHT31 (Temp/Humidity) + MPX5010DP (Breath Pressure/Flow Sensor) | |
| +----------------------------------------------+----------------------------------------------+ |
+-------------------------------------------------|-------------------------------------------------+
| SPI / I2C / Analog Signal
v
+---------------------------------------------------------------------------------------------------+
| 3. EMBEDDED PROCESSING & EDGE ML LAYER |
| +---------------------------------------------------------------------------------------------+ |
| | ESP32-S3 Dual-Core Microcontroller (240 MHz, 8MB PSRAM) | |
| | • Waveform Generator Engine (DPV Pulse Generation via External DAC MCP4725) | |
| | • Signal Conditioning & DSP Filtering (Savitzky-Golay Smoothing / Baseline Subtraction) | |
| | • Edge Tri-State Classification Engine (Peak Potential & Current Thresholding) | |
| | • Security Engine (AES-256 Record Encryption & Hardware SHA-256 Hash Chain) | |
| +----------------------------------------------+----------------------------------------------+ |
+-------------------------------------------------|-------------------------------------------------+
| Bluetooth Low Energy (BLE 5.0)
v
+---------------------------------------------------------------------------------------------------+
| 4. MOBILE & CONNECTIVITY LAYER |
| +---------------------------------------------------------------------------------------------+ |
| | Flutter Mobile Application (Android/iOS) | |
| | • BLE Secure Pairing & Real-time Voltammetric Curve Rendering | |
| | • GPS Location Tagging & Officer ID Metadata Capture | |
| | • Offline SQLite Store with Auto-Sync Queue | |
| +----------------------------------------------+----------------------------------------------+ |
+-------------------------------------------------|-------------------------------------------------+
| HTTPS / TLS 1.3 REST API
v
+---------------------------------------------------------------------------------------------------+
| 5. CLOUD & COMMAND PORTAL LAYER |
| +---------------------------------------------------------------------------------------------+ |
| | NCB Central Web Command Dashboard (React.js + Node.js / PostgreSQL) | |
| | • Geospatial Hotspot Analytics & Real-Time Incident Mapping | |
| | • Evidentiary Export (Section 65B Compliant Digital Certificates) | |
| | • Device Calibration & Firmware OTA Management | |
| +---------------------------------------------------------------------------------------------+ |
+---------------------------------------------------------------------------------------------------+
| Layer | Selected Technology | Why It Fits | Alternative Considered | Why Alternative Rejected |
|---|---|---|---|---|
| Microcontroller Hardware | ESP32-S3-WROOM-1 (8MB PSRAM) [ASSUMPTION] | Built-in Wi-Fi/BLE 5.0, dual-core 240MHz CPU for signal DSP, hardware cryptographic accelerator, extremely low power [RESEARCHED]. | Arduino Uno / Nano [KNOWN] | Extremely limited RAM (2KB), no native BLE/Wi-Fi, incapable of performing real-time DPV matrix calculations [INFERENCE]. |
| Potentiostat Front-End | Texas Instruments LMP91000 AFE [RESEARCHED] | Industry standard programmable electrochemical AFE; ultra-low power (<10µA); adjustable TIA gain ($2.75,\text{k}\Omega\text{--}350,\text{k}\Omega$) [RESEARCHED]. | Custom Discrete Op-Amp Circuit [INFERENCE] | High noise floor, prone to temperature drift, complex PCB layout required under hackathon timeline [INFERENCE]. |
| Data Acquisition ADC | ADS1115 16-bit I2C ADC [RESEARCHED] | Provides 16-bit resolution ($~7.81,\mu\text{V}/\text{LSB}$ at $V_{ref}=2.048,\text{V}$), vital for resolving nano-ampere ($nA$) electrochemical peak currents [RESEARCHED]. | ESP32 Internal ADC [KNOWN] | Highly non-linear, noisy, poor resolution at micro-volt levels [RESEARCHED]. |
| Sensors & Consumables | Commercial SPCE (Screen-Printed Carbon Electrodes) [RESEARCHED] | Low-cost disposable 3-electrode strips (Carbon Working, Carbon Counter, Ag/AgCl Reference); stable oxidation window up to +1.3V [RESEARCHED]. | Solid Platinum/Gold Disk Electrodes [RESEARCHED] | Requires manual polishing, cleaning, and recalibration between tests; impossible for field officers [INFERENCE]. |
| Mobile App Framework | Flutter 3.x (Dart) [ASSUMPTION] | Cross-platform (Android & iOS), high-performance BLE integration, native MPAndroidChart graph rendering [ASSUMPTION]. | React Native [KNOWN] | Inconsistent BLE background execution and lower graphical rendering performance for live curves [INFERENCE]. |
| Backend & Database | Node.js (Express) + PostgreSQL / PostGIS [ASSUMPTION] | Asynchronous I/O for heavy telemetry, native spatial querying for geospatial drug incident mapping [ASSUMPTION]. | Python Django + MySQL [KNOWN] | Slower async I/O throughput and heavier container footprint for cloud deployment [INFERENCE]. |
| Edge Signal Processing | C++ Arduino Framework + CMSIS-DSP [ASSUMPTION] | Optimized C++ linear algebra and FIR filtering libraries running directly on ESP32 dual cores [ASSUMPTION]. | Python MicroPython [KNOWN] | MicroPython incurs heavy execution latency during high-frequency ADC sampling loops [INFERENCE]. |
RAW DPV SIGNAL DSP SMOOTHING FEATURE EXTRACTION CLASSIFICATION
+------------------+ +------------------+ +-------------------------+ +------------------+
| Voltammogram | -> | Savitzky-Golay | -> | Peak Potential (E_peak) | -> | Decision Tree / | -> POSITIVE / NEGATIVE /
| Array (240 pts) | | Baseline Removal | | Peak Current (I_peak) | | 1D-CNN Model | INCONCLUSIVE
+------------------+ +------------------+ +-------------------------+ +------------------+
-- Device Audit & Calibration Table
CREATE TABLE devices (
device_id VARCHAR(64) PRIMARY KEY,
firmware_version VARCHAR(16) NOT NULL,
calibration_date TIMESTAMP NOT NULL,
status VARCHAR(16) CHECK (status IN ('ACTIVE', 'MAINTENANCE', 'DECOMMISSIONED'))
);
-- Test Log Table (Evidentiary Record)
CREATE TABLE test_records (
test_id UUID PRIMARY KEY DEFAULT gen_random_uuid(),
device_id VARCHAR(64) REFERENCES devices(device_id),
officer_badge_id VARCHAR(32) NOT NULL,
timestamp TIMESTAMP WITH TIME ZONE NOT NULL,
latitude DECIMAL(9,6) NOT NULL,
longitude DECIMAL(9,6) NOT NULL,
ambient_temp_c REAL NOT NULL,
ambient_humidity_pct REAL NOT NULL,
breath_volume_liters REAL NOT NULL,
result_class VARCHAR(16) CHECK (result_class IN ('POSITIVE', 'NEGATIVE', 'INCONCLUSIVE')),
detected_substances JSONB, -- e.g. {"THC": true, "Opioids": false, "Synthetics": false}
raw_dpv_curve_json JSONB NOT NULL, -- Array of (voltage, current) pairs
record_hash VARCHAR(64) NOT NULL, -- SHA-256 (test_id + device_id + timestamp + result + salt)
sync_status VARCHAR(16) DEFAULT 'PENDING' CHECK (sync_status IN ('PENDING', 'SYNCED', 'FAILED'))
);
(test_id + device_id + officer_id + timestamp + result_class). Any tampering with local app data invalidates the signature [INFERENCE, ASSUMPTION].+---------------------------------------------------------------------------------------------------+
| HACKATHON MVP SCOPE |
+-------------------------------------------------+-------------------------------------------------+
| IN SCOPE | OUT OF SCOPE / DESCRIBED |
+-------------------------------------------------+-------------------------------------------------+
| • Handheld physical prototype casing 3D print | • Forensically certified drug calibration |
| • ESP32-S3 + TI LMP91000 Potentiostat circuit | • Real controlled substance (THC/Heroin) testing|
| • SPCE strip socket interface | • Custom ASIC / IC fabrication |
| • Peltier micro-condensate trap assembly | • CDSCO medical device certification |
| • DPV scan generator & DSP smoothing algorithm | • Direct integration with national NCB servers |
| • Visual tri-state output (OLED & RGB LED) | • Commercial mass production tooling |
| • Flutter BLE Mobile App with local store & map | |
| • Chemical surrogate demonstration set | |
+-------------------------------------------------+-------------------------------------------------+
To ensure a convincing, scientifically rigorous live demonstration before SIH judges without possessing regulated narcotic substances [PS]:
Surrogate Chemical Mapping:
Live Demonstration Sequence:
Phase 1: Hardware Setup & Bench Calibration (Months 1-3)
Phase 2: Embedded Firmware & DPV Engine (Months 4-6)
Phase 3: Sample Intake & Condenser Assembly (Months 7-9)
Phase 4: Mobile App & BLE Integration (Months 10-11)
Phase 5: Testing, Validation & Final Polish (Month 12) -> Deadline: 30 Sept 2026
| Test Category | Target Objective | Testing Methodology | Pass Criteria |
|---|---|---|---|
| Functional Test | Verify end-to-end tri-state detection pipeline [PS]. | Run 50 automated tests with blank buffers vs surrogate drug solutions [ASSUMPTION]. | 100% correct classification of Positive, Negative, and Inconclusive states [ASSUMPTION]. |
| Voltammetric Precision | Verify repeatability of DPV peak potential acquisition [RESEARCHED]. | 20 consecutive DPV sweeps on $10,\mu\text{M}$ Acetaminophen solution [RESEARCHED, ASSUMPTION]. | Peak potential variation $\sigma(E_{peak}) \le \pm 10,\text{mV}$; peak current RSD $\le 5%$ [RESEARCHED, ASSUMPTION]. |
| Condensation Efficiency | Ensure sufficient liquid capture from human breath [RESEARCHED]. | Measure liquid volume collected from 10 volunteer expirations across 15 seconds [RESEARCHED, ASSUMPTION]. | Minimum $50,\mu\text{L}$ EBC liquid collected reliably in $\le 40,\text{seconds}$ [RESEARCHED, ASSUMPTION]. |
| Interferent Rejection | Eliminate false positives from common dietary/breath items [RESEARCHED]. | Test breath immediately after subject consumes alcohol, cigarettes, coffee, and mouthwash [RESEARCHED, ASSUMPTION]. | Zero false positive flags on Negative control matrices; background shift $\le 10%$ [RESEARCHED, ASSUMPTION]. |
| Battery Life & Power | Confirm continuous field shift operation [INFERENCE]. | Continuous cyclic execution of DPV sweeps on battery power [ASSUMPTION]. | $\ge 200$ full test cycles or 10 hours standby on single charge [ASSUMPTION]. |
| BLE & Offline Resilience | Validate zero data loss during cellular/Bluetooth disconnection [INFERENCE]. | Perform 20 test runs with mobile phone turned off, then power phone on [ASSUMPTION]. | 100% of buffered records in ESP32 SPIFFS successfully sync to mobile app [ASSUMPTION]. |
| Risk Event | Likelihood | Impact | Severity | Mitigation Strategy |
|---|---|---|---|---|
| Inadequate EBC Liquid Volume in Low Humidity | Medium | High | High | Integrate a micro-wicking cellulose pad directly above the SPCE working electrode that actively draws exhaled aerosol droplets even at low condensation volumes [RESEARCHED, ASSUMPTION]. |
| LMP91000 Resolution Limits for Low Concentrations | Medium | Medium | Medium | Augment the LMP91000 with a high-resolution 16-bit external ADC (ADS1115) and external precision voltage reference (LM4040) to resolve nano-ampere peak currents [RESEARCHED, ASSUMPTION]. |
| Sensor Surface Bio-Fouling from Saliva | High | Medium | Medium | Install a physical droplet baffle/filter matrix in the intake mouthpiece to block macro-saliva droplets while allowing micro-aerosols to pass through [RESEARCHED, ASSUMPTION]. |
| Cross-Contamination Between Tests | Medium | High | High | Mandate single-use disposable mouthpieces and disposable SPCE strips; integrate optical strip-insertion sensors that reject previously used strips [INFERENCE, ASSUMPTION]. |
| Temperature Drift Altering Peak Potentials | High | Medium | Medium | Implement real-time SHT31 temperature monitoring and apply automated software peak-shift compensation equations ($E_{corr} = E_{meas} - \alpha \cdot \Delta T$) [RESEARCHED, ASSUMPTION]. |
+---------------------------------------------------------------------------------------------------+
| HACKATHON PROTOTYPE COST BREAKDOWN |
+----------------------------------------------------+----------------------------------------------+
| Component Item | Estimated Cost (INR ₹) |
+----------------------------------------------------+----------------------------------------------+
| ESP32-S3 Microcontroller Board | ₹ 650 |
| TI LMP91000 Potentiostat Module + ADS1115 ADC | ₹ 1,200 |
| MPX5010DP Pressure Transducer + SHT31 Sensor | ₹ 1,100 |
| Peltier Condensation Element + Heatsink/Fan | ₹ 850 |
| 3.7V 2600mAh LiFePO4 Battery + TP4056 Charger | ₹ 550 |
| 1.3" OLED Display + Buttons + RGB LED + Buzzer | ₹ 450 |
| 3D-Printed Enclosure & Microfluidic Intake Duct | ₹ 800 |
| SPCE Sensor Strips (Pack of 20) | ₹ 1,000 |
| Passives, PCB Prototype, Wiring & Connectors | ₹ 900 |
+----------------------------------------------------+----------------------------------------------+
| TOTAL HACKATHON PROTOTYPE COST | ₹ 7,500 [ASSUMPTION] |
+----------------------------------------------------+----------------------------------------------+
| Key Feature / Metric | Generic SIH Submissions | Proposed NarkoBreath Solution | Requirement Advantage |
|---|---|---|---|
| Sample Matrix | Bulk powder testing or generic saliva swabs [INFERENCE]. | Pure exhaled breath aerosol condensation (EBC) [RESEARCHED, ASSUMPTION]. | Directly fulfills breath-analysis requirement for non-invasive roadside screening [PS]. |
| Sensing Mechanism | Unselective MOS gas sensors prone to extreme alcohol/humidity false positives [RESEARCHED]. | Multi-channel Differential Pulse Voltammetry (DPV) on SPCE strips [RESEARCHED]. | Meets explicit requirement for electrochemical sensing technology [PS]. |
| Analyte Spectrum | Single-substance focus (mostly alcohol or THC only) [RESEARCHED]. | Multi-analyte resolution across Cannabis, Opioids, and Synthetic Drugs [RESEARCHED]. | Directly covers all three target narcotic categories specified by NCB [PS]. |
| Decision Output | Raw voltage numbers or complex plots confusing field officers [INFERENCE]. | Immediate, deterministic Tri-State result (Positive / Negative / Inconclusive) + OLED/BLE [PS, INFERENCE]. | Operable by field constables with minimal training [PS]. |
| Evidentiary Security | Plain text serial data logs easily manipulated in court [INFERENCE]. | Encrypted BLE 5.0 stream + SHA-256 digital signature + GPS/timestamp chain-of-custody [INFERENCE, ASSUMPTION]. | Admissible under law enforcement digital evidence standards [INFERENCE]. |
The team should proceed with building the proposed NarkoBreath system. The combination of Exhaled Breath Condensate (EBC) aerosol capture, disposable Screen-Printed Carbon Electrodes (SPCE), TI LMP91000 potentiostat AFE, and ESP32 edge processing represents the most technically feasible, low-cost, scientifically validated, and hackathon-achievable architecture for SIH26230 [RESEARCHED, ASSUMPTION].
Acquisition of reliable Screen-Printed Carbon Electrode (SPCE) strips and achieving repeatable liquid contact between the micro-condensed breath droplets and the 3-electrode reaction surface without manual pipetting [RESEARCHED, ASSUMPTION].
Variability in exhaled breath condensate volume in high-temperature, low-humidity field environments leading to incomplete electrode coverage and potential false negative or inconclusive results [RESEARCHED, ASSUMPTION].
Designing an automated micro-condensation intake channel that reliably condenses $50\text{--}100,\mu\text{L}$ of breath aerosol in under 30 seconds while preventing macro-saliva contamination from reaching the sensor strip [RESEARCHED, ASSUMPTION].
88/100 (High buildability; relies on accessible COTS hardware components, standard C++ signal processing, and clear chemical surrogate demonstration protocols well within the technical capacity of a 4–6 student engineering team) [INFERENCE, ASSUMPTION].
High Confidence (85%) in achieving a working hardware prototype that demonstrates full technical feasibility, rapid response time, clear tri-state output, and mobile app integration prior to the 30 September 2026 deadline [PS, INFERENCE, ASSUMPTION].
Title: Recent advances in electrochemical sensor technologies for THC detection—a narrative review
Title: Cannabinoids detected in exhaled breath condensate after cannabis use
Title: Detecting opioid metabolites in exhaled breath condensate (EBC)
Title: Texas Instruments LMP91000 Configurable AFE Potentiostat Datasheet
Title: Hound Breathalyzer – Detect Recent Cannabis Use
What we think about this platform, and how it can help people solve SIH problems.
" 30M+ Google Gemini tokens went into researching, analyzing, and understanding all 233 SIH problem statements to make them easier to explore and solve. "
" The platform makes SIH problem statements much easier to understand. Having everything from the problem details to the procedure in one place. "
" Oh, you got ads? Well, we need to make money too! But, you can use our platform to help you win SIH and take home the prize money. "